ZT-24/250 24kV250A Loadbreak Elbow Connector

Get our Buyer's Guide
Our experts will break down everything you need to know so you can choose the right product for your business.
Product Details

The ZT-24/250 24kV250A Loadbreak Elbow Connector provides a fully shielded and fully submersible separable connection when used with an appropriate bushing or plug. Built-in capacitive test points can determine circuit status or install fault indicators. No minimum phase spacing requirements. Mounting can be vertical, horizontal or any angle in between.

 

Provides a fully screened and fully submersible separable connection when mated with the proper bushing or plug.

Built-in capacitive test point to determine the circuit status or install a fault indicator.

No minimum phase clearance requirements.

Mounting can be vertical, horizontal, or any angle in between.

 

Application

For connection of polymeric cable to transformers, switchgear, motors and other equipment with a premoulded separable connector.

For indoor and outdoor installations,

System voltage up to 24 kV.

Continuous current250A (300 A overload for 8 hours).

Cable particulars:

  • Polymeric cable (XLPE,EPR,etc.)
  • Copper or aluminum conductors
  • Semiconducting or metallic screens
  • Conductor size 25-120 mm2

 

Standards

Will meet the requirements of GB/T12706.4-2002及IEC60502.4-2005.

 

Scope of Delivery

Elbow connector

Copper or Aluminium Conductor cable lug

Loadbreak Probe

Steel Installation Tool

Clearing Paper

Silicone Lubricant

Installation Instruction Sheet

Quality Certificate

 

 

Inference Information

 

Installation

1. Without any special tools.

2. When finish the installation of elbow connector, the power can be supply directly.

3. Can be used together with the bushing, cable connector and junction witch meet the requirement EN50180/EN50181DIN47636/HN52-S-61.

 

 

Product Structure

 

1. Conducting Rod:Tin-plated copper pin screws into the conductor contact with the supplied hex key.

2. SEMI-CONDUCTIVE INSERT: Moulded EPDM conducting rubber screen controls electrical stress.

3. Insulation: Moulded EPDM insulating rubber is formulated and mixed in-house to ensure high quality.

4. Pulling Eye: Encapsulated stainless steel pulling eye with a detent to position the bail.

5. Capacitive Test Point: Capacitive test point provides means to check circuit status. A moulded EPDM conducting rubber cap provides a watertight seal.

6. Stress Relief:The configuration of the outer screen and the cable adapter provide cable stress relief.

7. Cable Adapter: The sized opening provides an interference fit to maintain a watertight seal.

8. Grounding Eye: Moulded into the external screen for connection of an earthing wire.

9. SEMI-CONDUCTIVE SHIELD:Moulded EPDM conducting rubber mates with the cable screen to maintain screen continuity and ensure that the assembly is at earth potential.

10. Conductor Cable lug: Inertia welded bimetallic compression connector accepts copper or aluminum conductors.

 

Technical Parameters
Ratings Overview

Description

Parameters

(Um)Maximum system voltage

24kV

Impulse withstand voltage

125kV

AC withstand voltage, 5min

54kV

Continuous operating current

250A

Overload (8hrs. Max.)

300A

Short circuit withstand

12.5kA/1s

 

 

Order Information

 

The cable meet the requirements of GB/T12706 in 7/10kV, the order information as following.

Reference No.

Conductor cross

section (mm²)

Stretch range over

insulation (mm)

Size of

stress cone

ZT-10/250-25

25

16.3-19.9

A

ZT-10/250-35

35

16.3-19.9

A

ZT-10/250-50

50

16.3-19.9

A

ZT-10/250-70

70

19.8-23.5

B

ZT-10/250-95

95

23.1-27.1

F

ZT-10/250-120

120

23.1-27.1

F

NOTE: The cable range is the basic element for choosing the product's type. The conductor size is just for a reference.

 

 

The cable meet the requirements of GB/T12706 in 12/20kV, the order information as following.

Reference No.

Conductor cross

section (mm²)

Stretch range over

insulation (mm)

Size of

stress cone

ZT-24/250-35

35

23.1-27.1

F

ZT-24/250-50

50

23.1-27.1

F

ZT-24/250-70

70

23.6-26.4

H

ZT-24/250-95

95

23.6-26.4

H

ZT-24/250-120

120

27.9-33.5

J

NOTE: The cable range is the basic element for choosing the product's type. The conductor size is just for a reference.

Related News
The Heat Shrink Cable Intermediate Connector is easy to install
In the field of electric power engineering, the application of Heat Shrink Cable Intermediate Connector is becoming more and more widespread. Its installation convenience not only affects the construction efficiency but also relates to whether the entire power system can be built quickly and operate stably. An in-depth exploration of various aspects of its installation convenience is of crucial significance for optimizing the construction process of electric power projects and reducing labor costs. A Comprehensive Analysis of the Installation Convenience of Heat Shrink Cable Intermediate Connector
how to replace a circuit breaker
Circuit breakers are essential components in electrical systems, protecting circuits from overloads and short circuits. Knowing how to replace a circuit breaker is a valuable skill for homeowners and electricians alike. In this article, we will also touch upon some aspects related to Vacuum Circuit Breakers.
Separable Connector Installation Guide
Installing a separable connector correctly is crucial to ensure the reliable and safe operation of electrical connections. Follow these steps carefully to achieve a proper installation.

GET A QUOTE

GET IN TOUCH NOW
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All