JDZ10-3、6、10B indoor fully insulated voltageTransformer

Get our Buyer's Guide
Our experts will break down everything you need to know so you can choose the right product for your business.
Product Details
Description and meaning of model

 

JDZ10-3, 6, 10B indoor fully insulated voltage Transformer adopts epoxy resin vacuum casting fully enclosed structure, with good insulation performance and mechanical strength. This series of products are divided into different voltage levels, including 3kV, 6kV and 10kV, to meet the needs of different power systems. They are suitable for power systems with a rated frequency of 50Hz or 60Hz, and are widely used in substations, power plants, switch cabinets and electric energy metering cabinets.

 

 

Characteristic of structure

 

This product is epoxy resin casted with totally-enclosed structure. lt adopts the high grade steel sheet and strict heat treatment. The core, the primary windings and the secondary windings are casted by epoxy resin together. Anti-pollution and moisture-proof.Beside the secondary outlet terminal, there is terminal box on which it could elicit the secodary connection at three directions. The connection is very convenient, and the box could prevent someone from stealing the power electricity.

 

 

Application scope

 

Power factor of load: COSΦ=0.8(lagging);

Rated frequency: 50 or 60Hz;

Anti-Pollution grade: Class ll;

Ambient temperature: -5 ℃ -40 ℃ ,daily average temperature not more than 30℃ ;

Altitude ≤ 1000m;

Standard: GB 1207-2006

 

Technical Parameters
Type Rated voltage (V)  Rated output of secondary winding (VA) Thermal limitiong output of winding (VA) Rated insulating level (kV)
Primary winding Secondary winding 0.2 Class 0.5 Class
JDZ10-3B 3000 100 20 30 200 3.6/25/40
JDZ10-6B 6000 100 20 50 200 7.2/32/60
220 500-1000
100/100 15 20 300
100/220 500
JDZ10-10B 10000 100 30 80 400 12/42/75
220 500-1000
100/100 15 20 200
100/220 500

Note: any special requirements can be negotiated with us

 

Related News
The difference between current transformer (CT) and voltage transformer
Current transformer (CT) is a special instrument transformer that operates on the principle of electromagnetic induction. Its secondary winding proportionally senses a secondary current that is strict
How to Select the Right Current Limiting Fuse for Your Electrical Equipment?
When it comes to choosing the right current - limiting fuse, many people have numerous questions.
Cost - effectiveness of Drop Out Fuses in Electrical Distribution Networks
In electrical distribution networks, ensuring both reliable power supply and cost - efficiency is of utmost importance.

GET A QUOTE

GET IN TOUCH NOW
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All