JDZC-6、10 Indoor Voltage Transformer

Get our Buyer's Guide
Our experts will break down everything you need to know so you can choose the right product for your business.
Product Details
Description and meaning of model

 

JDZC-6、10 Indoor Voltage Transformer is indoor type, it is epoxy resin casted semi-closed structure. lt is designed for use of measurement of voltage, electronic energy and relay protection in the power system with rated frequency 50Hz and rated voltage 10kV or below. And it could provide the power supply for the mechanism.

 

 

Characteristic of structure

 

JDZC-6,10 type voltage transformer is epoxy resin casted of semi-closed structure. The core adopts high grade cold rolled silicon-steel sheet. With small size, light weight, small space for installation, All windings are completely casted in the epoxy resin. anti-impulse and resist mechanism pressure. Keep windings without moisture. The down-lead terminal signs of the primary windings are A , B, the down-lead terminal signs of the secondary windings are a, b; these signs are clearly marked on the surface of the product.Beside the earthing signs, the earthing bolts is useo for earthing. The whole structure is compact and it is convenient for use.

 

 

Application scope

 

Power factor of load: COSΦ=0.8(lagging);

Rated frequency: 50 or 60Hz;

Anti-Pollution grade: Class ll;

Ambient temperature: -5 ℃ -40 ℃ ,daily average temperature not more than 30℃ ;

Altitude ≤ 1000m;

Standard: GB 1207-2006

 

Technical Parameters
Type Rated voltage (V)  Rated output of secondary winding (VA) Thermal limitiong output of 220V (VA) Rated insulating level (kV)
Primary winding Secondary winding 0.2 0.5 1 3
JDZC-6 6000 220 20 50 80 200 800 7.2/32/60
100/220
JDZC-10 10000 220 30 80 120 300 1500 12/42/75
100/220

Note: any special requirements can be negotiated with us

 

Related News
The difference between current transformer (CT) and voltage transformer
Current transformer (CT) is a special instrument transformer that operates on the principle of electromagnetic induction. Its secondary winding proportionally senses a secondary current that is strict
How to Select the Right Current Limiting Fuse for Your Electrical Equipment?
When it comes to choosing the right current - limiting fuse, many people have numerous questions.
Cost - effectiveness of Drop Out Fuses in Electrical Distribution Networks
In electrical distribution networks, ensuring both reliable power supply and cost - efficiency is of utmost importance.